va-Q-med

The va-Q-med is a box optimized for integrator networks and wholesaler operations. It has a robust outer box and is designed for a long lifetime. The multi-use box is GDP compliant and is a great option for last mile or lab distribution. va-Q-tec offers the va-Q-med both as a purchase option or as a convenient rental option. 

Advantages of va-Q-med

  • Designed for domestic distribution
  • Two qualified performance levels without payload according to ISTA 7E (summer & winter profile): Standard with true 36h and more & Premium with true 54h and more
  • 3 qualified temperature ranges from -25 °C (without dry ice) to + 25 °C available (homogenous in every part of the box)
  • Comprehensive 2 size portfolio: from 5 L to 18 L payload volume, optimized for fully automated process
  • Smooth and cost saving operations: Intuitive design & all-season packout
  • Cost & energy efficient: Cooled & non-cooled goods can be transported in one vehicle without dry ice
  • Core Components & Technology “MADE IN GERMANY”

Properties of va-Q-med

Dimensions

va-Q-med 7

Payload : 7 l

Outer dimension (L x W x H) : 15.75 x 11.81 x 12.80 inch

Inner dimension (L x W x H) : 9.65 x 6.50 x 6.50 inch

va-Q-med 21

Payload : 18 l

Outer dimension (L x W x H) : 23.62 x 15.75 x 13.58 inch

Inner dimension (L x W x H) : 17.32 x 9.84 x 6.30 inch

va-Q-med 7 Standard +05G

ISTA 7E Summer

Performance : ≥ 22 hrs

KelvinHours : ≥ 473 Khrs

ISTA 7E Winter

Performance : ≥ 72 hrs

KelvinHours : n.a. Khrs

va-Q-med 7 Premium +05G

ISTA 7E Summer

Performance : ≥ 30 hrs

KelvinHours : ≥ 684 Khrs

ISTA 7E Winter

Performance : ≥ 72 hrs

va-Q-med 7 Standard +22G

ISTA 7E Summer

Performance : ≥ 48 hrs

KelvinHours : ≥ 341 Khrs

ISTA 7E Winter

Performance : ≥ 20 hrs

KelvinHours : ≤ -242 Khrs

va-Q-med 7 Premium +22G

ISTA 7E Summer

Performance : ≥ 49 hrs

KelvinHours : ≥ 368 Khrs

ISTA 7E Winter

Performance : ≥ 33 hrs

KelvinHours : ≤ -406 Khrs

va-Q-med 7 Standard -21G

ISTA 7E Summer

Performance : ≥ 18 hrs

KelvinHours : ≥ 844 Khrs

va-Q-med 7 Premium -21G

ISTA 7E Summer

Performance : ≥ 34 hrs

KelvinHours : ≥ 1612 Khrs

va-Q-med 21 Standard +05G

ISTA 7E Summer

Performance : ≥ 36 hrs

KelvinHours : ≥ 806 Khrs

ISTA 7E Winter

Performance : ≥ 72 hrs

va-Q-med 21 Premium +05G

ISTA 7E Summer

Performance : ≥ 47 hrs

KelvinHours : ≥ 1043 Khrs

ISTA 7E Summer

Performance : ≥ 72 hrs

va-Q-med 21 Standard +22G

ISTA 7E Summer

Performance : ≥ 69 hrs

KelvinHours : ≥ 504 Khrs

ISTA 7E Winter

Performance : ≥ 32 hrs

KelvinHours : ≤ -410 Khrs

va-Q-med 21Premium +22G

ISTA 7E Summer

Performance : ≥ 72 hrs

KelvinHours : ≥ 540 Khrs

ISTA 7E Winter

Performance : ≥ 39 hrs

KelvinHours : ≤ 503 Khrs

va-Q-med 21 Standard -21G

ISTA 7E Summer

Performance : ≥ 23 hrs

KelvinHours : ≥ 1083 Khrs

va-Q-med 21 Premium -21G

ISTA 7E Summer

Performance : ≥ 41 hrs

KelvinHours : ≥ 1935 Khrs

We are there for you!

Our experts are happy to advise you on any thermal problem. We support you in all phases,

from your initial questions to the implementation.

Get help