The va-Q-med is a box optimized for integrator networks and wholesaler operations. It has a robust outer box and is designed for a long lifetime. The multi-use box is GDP compliant and is a great option for last mile or lab distribution. va-Q-tec offers the va-Q-med both as a purchase option or as a convenient rental option. 

Advantages of va-Q-med

  • Designed for domestic distribution
  • Two qualified performance levels without payload according to ISTA 7E (summer & winter profile): Standard with true 36h and more & Premium with true 54h and more
  • 3 qualified temperature ranges from -25 °C (without dry ice) to + 25 °C available (homogenous in every part of the box)
  • Comprehensive 2 size portfolio: from 5 L to 18 L payload volume, optimized for fully automated process
  • Smooth and cost saving operations: Intuitive design & all-season packout
  • Cost & energy efficient: Cooled & non-cooled goods can be transported in one vehicle without dry ice
  • Core Components & Technology “MADE IN GERMANY”

Properties of va-Q-med

Dimensions

va-Q-med 7

Payload : 7 l

Outer dimension (L x W x H) : 15.75 x 11.81 x 12.80 inch

Inner dimension (L x W x H) : 9.65 x 6.50 x 6.50 inch

va-Q-med 21

Payload : 18 l

Outer dimension (L x W x H) : 23.62 x 15.75 x 13.58 inch

Inner dimension (L x W x H) : 17.32 x 9.84 x 6.30 inch

va-Q-med 7 Premium -21G

ISTA 7E summer

Performance : ≥ 33 hrs

KelvinHours : ≥ 1564 Khrs

va-Q-med 7 Standard -21G

ISTA 7E summer

Performance : ≥ 18 hrs

KelvinHours : ≥ 844 Khrs

va-Q-med 7 Standard +05G

ISTA 7E summer

Performance : ≥ 21 hrs

KelvinHours : ≥ 466 Khrs

ISTA 7E winter

Performance : ≥ 72 hrs

KelvinHours : n.a.

va-Q-med 7 Premium +05G

ISTA 7E summer

Performance : ≥ 29 hrs

KelvinHours : ≥ 661 Khrs

ISTA 7E winter

Performance : ≥ 72 hrs

KelvinHours : n.a.

va-Q-med 7 Standard +22G

ISTA 7E summer

Performance : ≥ 47 hrs

KelvinHours : ≥ 333 Khrs

ISTA 7E winter

Performance : ≥ 20 hrs

KelvinHours : ≤ -242 Khrs

va-Q-med 7 Premium +22G

ISTA 7E summer

Performance : ≥ 48 hrs

KelvinHours : ≥ 360 Khrs

ISTA 7E winter

Performance : ≥ 33 hrs

KelvinHours : ≤ -406 Khrs

va-Q-med 21 Standard -21G

ISTA 7E summer

Performance : ≥ 23 hrs

KelvinHours : ≥ 1083 Khrs

va-Q-med 21 Premium -21G

ISTA 7E summer

Performance : ≥ 40 hrs

KelvinHours : ≥ 1888 Khrs

va-Q-med 21 Standard +05G

ISTA 7E summer

Performance : ≥ 36 hrs

KelvinHours : ≥ 806 Khrs

ISTA 7E winter

Performance : ≥ 72 hrs

KelvinHours : n.a.

va-Q-med 21 Premium +05G

ISTA 7E summer

Performance : ≥ 47 hrs

KelvinHours : ≥ 1043 Khrs

ISTA 7E winter

Performance : ≥ 72 hrs

KelvinHours : n.a.

va-Q-med 21 Standard +22G

ISTA 7E summer

Performance : ≥ 68 hrs

KelvinHours : ≥ 496 Khrs

ISTA 7E winter

Performance : ≥ 28 hrs

KelvinHours : ≤ -344 Khrs

va-Q-med 21Premium +22G

ISTA 7E Summer

Performance : ≥ 72 hrs

KelvinHours : ≥ 540 Khrs

ISTA 7E Winter

Performance : ≥ 39 hrs

KelvinHours : ≤ 503 Khrs