va-Q-vip F XPS

va-Q-vip F XPS is a vacuum insulation panel with XPS lamination for construction applications. The core itself is non-combustible (fire class A1), va-Q-vip F XPS is inflammable (construction materials class DIN 4102-B2). va-Q-vip F is approved for general construction purposes in accordance with approval number Z-23.11-1658, of the "Deutsches Institut für Bautechnik (DIBT)".

va-Q-vip F XPS elements stand out because of their smooth edges and corners. This is due to the special edge folding technique "va-Q-seam". Individual elements can therefore be joined together almost seamlessly.

Advantages of va-Q-vip F XPS

  • Particularly suitable for construction elements, built-in parts, floor and ceiling applications
  • Additional surface protection through XPS layer
  • Enhanced usable room area due to thinner insulation material
  • Smooth edges and no foil overlaps due to patented va-Q-seam technology
  • Various standard sizes on stock
  • Approved for general construction purposes after Z-23.11-1658 and ETA-17/0926
  • Long lifetime due to optimized panel design
  • 100 % quality control with the patented gas pressure measurement system (va-Q-check®)
  • Sustainable product: manufactured according to the highest quality and environmental standards (DIN EN ISO 14021)
  • Climate neutral production in Germany

Properties of va-Q-vip F XPS

Specifications

Details : Enhanced usable room area due to thinner insulation material
Smooth edges and no foil overlaps due to patented va-Q-seam technology
Various standard sizes on stock
Approved for general construction purposes according to Z-23.11-1658 and ETA-17/0926
Long lifetime due to optimized panel design
100 % quality control with the patented gas pressure measurement system (va-Q-check)
Sustainable product (recyclable core material)

Color : purple

Density : 180 – 210 kg/m³ (d ≥ 20 mm); 180 – 250 kg/m³ (d < 20 mm) according to DIN EN 1602 [kg/m³]

temperature resistance : -75 – 80 °C (temporary up to 120 °C)

Internal gas pressure at delivery : ≤ 5 mbar (at delivery)

Gas pressure rise : < 1,5 mbar/year (d = 20 mm)

heat transfer coefficient (U-Wert) : 0,22 W/(m²∙K) (d = 20 mm) [W/(m²*K)]

Other features

Dimensions & tolerances :

spec. heat capacity : 0,8 - 1,0 kJ/kgK (at room temperature) [J/kg*K]

pressure limitation : ≥ 150 kPa bei 10 % Stauchung nach DIN EN 826 [kPa]