va-Q-med

The va-Q-med is a box optimized for integrator networks and wholesaler operations. It has a robust outer box and is designed for a long lifetime. The multi-use box is GDP compliant and is a great option for last mile or lab distribution. va-Q-tec offers the va-Q-med both as a purchase option or as a convenient rental option. 

Advantages of va-Q-med

  • Designed for domestic distribution
  • Two qualified performance levels without payload according to ISTA 7E (summer & winter profile): Standard with true 36h and more & Premium with true 54h and more
  • 5 qualified temperature ranges for shipments from -50 °C (without dry ice) to + 20 °C available (homogenous in every part of the box)
  • 2 size box portfolio: from 5 L to 18 L payload volume, optimized for fully automated process
  • Smooth and cost-saving operations: Intuitive design, all-season pack-out, transport of cooled & non-cooled goods in one vehicle
  • High energy efficiency enables low CO₂ emissions, product carbon footprint calculations are available
  • Produced in a global carbon neutral company. Technology “MADE IN GERMANY”
  • TempChain Service Software: Centralized management of the entire TempChain logistics process
  • Optional service: 100% TempChain visibility managed by va-Q-nection

Properties of va-Q-med

Dimensions

va-Q-med 7

Payload : 7 l

Außenmaß (L x B x H) : 400 x 300 x 325 mm

Innenmaß (L x B x H) : 245 x 165 x 165 mm

va-Q-med 21

Payload : 18 l

Außenmaß (L x B x H) : 600 x 400 x 345 mm

Innenmaß (L x B x H) : 440 x 250 x 160 mm

va-Q-med 7 Standard +05G

ISTA 7E summer

Performance : ≥ 21 Std

KelvinHours : ≥ 466 Khrs

ISTA 7E winter

Performance : > 72 Std

KelvinHours : n.a.

va-Q-med 7 Premium +05G

ISTA 7E summer

Performance : ≥ 29 Std

KelvinHours : ≥ 661 Khrs

ISTA 7E winter

Performance : > 72 Std

KelvinHours : n.a.

va-Q-med 7 Standard +22G

ISTA 7E summer

Performance : ≥ 47 Std

KelvinHours : ≥ 333 Khrs

ISTA 7E winter

Performance : ≥ 20 Std

KelvinHours : ≤ -242 Khrs

va-Q-med 7 Premium +22G

ISTA 7E summer

Performance : ≥ 48 Std

KelvinHours : ≥ 360 Khrs

ISTA 7E winter

Performance : ≥ 33 Std

KelvinHours : ≤ -406 Khrs

va-Q-med 7 Standard -21G

ISTA 7E summer

Performance : ≥ 18 Std

KelvinHours : ≥ 844 Khrs

va-Q-med 7 Premium -21G

ISTA 7E summer

Performance : ≥ 33 Std

KelvinHours : ≥ 1564 Khrs

va-Q-med 7 Premium -26G

ISTA 7E summer

Performance : ≥ 18 Std

KelvinHours : ≥ 936 Khrs

va-Q-med 7 Premium -37G

ISTA 7E summer

Performance : ≥ 11 Std

KelvinHours : ≥ 741 Khrs

va-Q-med 7 Premium -50G

ISTA 7E summer

Performance : ≥ 16 Std

KelvinHours : ≥ 1238 Khrs

va-Q-med 21 Standard +05G

ISTA 7E summer

Performance : ≥ 36 Std

KelvinHours : ≥ 806 Khrs

ISTA 7E winter

Performance : > 72 Std

KelvinHours : n.a.

va-Q-med 21 Premium +05G

ISTA 7E summer

Performance : ≥ 47 Std

KelvinHours : ≥ 1043 Khrs

ISTA 7E winter

Performance : ≥ 72 Std

KelvinHours : n.a.

va-Q-med 21 Standard +22G

ISTA 7E summer

Performance : ≥ 68 Std

KelvinHours : ≥ 496 Khrs

ISTA 7E winter

Performance : ≥ 28 Std

KelvinHours : ≤ -344 Khrs

va-Q-med 21Premium +22G

ISTA 7E summer

Performance : ≥ 72 Std

KelvinHours : ≥ 540 Khrs

ISTA 7E winter

Performance : ≥ 39 Std

KelvinHours : ≤ -503 Khrs

va-Q-med 21 Standard -21G

ISTA 7E summer

Performance : ≥ 23 Std

KelvinHours : ≥ 1083 Khrs

va-Q-med 21 Premium -21G

ISTA 7E summer

Performance : ≥ 40 Std

KelvinHours : ≥ 1888 Khrs

va-Q-med 21 Premium -26G

ISTA 7E summer

Performance : ≥ 28 Std

KelvinHours : ≥ 1330 Khrs

va-Q-med 21 Premium -37G

ISTA 7E summer

Performance : ≥ 22 Std

KelvinHours : ≥ 1362 Khrs

va-Q-med 21 Premium -50G

ISTA 7E summer

Performance : ≥ 22 Std