va-Q-tainer

The va-Q-tainer is an advanced passive container, perfect for the global transportation of clinical and pharmaceutical goods. The container saves costs and simplifies handling in challenging environments. With pay-per-use-rental, scalable TempChain Services and a growing global network, the va-Q-tainer eases the work of pharmaceutical cold chain managers worldwide. The award winning container insulation enables deviation-free shipping of temperature sensitive goods, according to requirements worldwide.

Advantages of va-Q-tainer

  • Door-to-door solution for an unbroken TempChain
  • Qualified performance without payload at ambient temperature of 30 °C and 0 °C: True 120h and more
  • 5 qualified temperature ranges from -80 °C to +25 °C available (as low as -40 °C without dry ice)
  • Comprehensive 4 size container portfolio from 1 Euro pallet to 2 US pallets payload volume
  • PMC pallet optimized: 4 Euro pallets (with 4 EUROx) or 4 US pallets (with 2 TWINx)
  • Smooth and cost saving operations: “ready to load & go” service for rental containers
  • Advanced passive technology & dry ice free (as low as -40 °C): High energy efficiency and low CO2 Emission
  • Designed for multi-use: Re-qualification of rental containers with va-Q-check® secures day-one-validation
  • Core Components & Technology “MADE IN GERMANY”
  • TempChain Service Software: Centralized management of the entire TempChain logistics process

Properties of va-Q-tainer

Dimensions

va-Q-tainer EUROx

Payload : 1200 l

Outer dimension (L x W x H) : 56.02 x 43.03 x 62.20 inch

Inner dimension (L x W x H) : 47.24 x 33.46 x 46.06 inch

va-Q-tainer USx

Payload : 1800 l

Outer dimension (L x W x H) : 56.02 x 58.66 x 62.20 inch

Inner dimension (L x W x H) : 47.24 x 49.21 x 46.06 inch

va-Q-tainer XLx

Payload : 2500 l

Outer dimension (L x W x H) : 74.41 x 58.66 x 62.20 inch

Inner dimension (L x W x H) : 64.57 x 49.21 x 48.03 inch

va-Q-tainer TWINx

Payload : 3200 l

Outer dimension (L x W x H) : 93.70 x 58.66 x 62.20 inch

Inner dimension (L x W x H) : 83.07 x 49.21 x 48.03 inch

va-Q-tainer EUROx Dry Ice

va-Q-tec summer

Performance : ≥ 103 hrs

KelvinHours : ≥ 10352 Khrs

va-Q-tainer EUROx -37G

va-Q-tec controlled summer

Performance : ≥ 96 hrs

KelvinHours : ≥ 4790 Khrs

va-Q-tec extreme summer

Performance : ≥ 59 hrs

KelvinHours : n.a.

va-Q-tainer EUROx -21G

va-Q-tec summer

Performance : ≥ 102 hrs

KelvinHours : ≥ 5110 Khrs

va-Q-tec extreme summer

Performance : ≥ 66 hrs

KelvinHours : n.a.

va-Q-tainer EUROx +05G

va-Q-tec summer

Performance : ≥ 125 hrs

KelvinHours : ≥ 3163 Khrs

va-Q-tec winter

Performance : > 144 hrs

KelvinHours : < -676 Khrs

va-Q-tec extreme summer

Performance : ≥ 62 hrs

KelvinHours : n.a.

va-Q-tec extreme winter

Performance : ≥ 33 hrs

KelvinHours : n.a.

va-Q-tainer EUROx +18G/+23G

va-Q-tec summer

Performance : ≥ 120 hrs

KelvinHours : ≥ 1176 Khrs

va-Q-tec winter

Performance : ≥ 120 hrs

KelvinHours : ≤ 2376 Khrs

va-Q-tec extreme summer

Performance : ≥ 30 hrs

KelvinHours : n.a.

va-Q-tec extreme winter

Performance : ≥ 56 hrs

KelvinHours : n.a.

va-Q-tainer USx Dry Ice

va-Q-tec summer

Performance : ≥ 127 hrs

KelvinHours : ≥ 12687 Khrs

va-Q-tainer USx -37G

va-Q-tec controlled summer

Performance : ≥ 99 hrs

KelvinHours : ≥ 4950 Khrs

va-Q-tec extreme summer

Performance : ≥ 63 hrs

KelvinHours : n.a.

va-Q-tainer USx -21G

va-Q-tec summer

Performance : ≥ 113 hrs

KelvinHours : ≥ 5683 Khrs

va-Q-tec extreme summer

Performance : ≥ 83 hrs

KelvinHours : n.a.

va-Q-tainer USx +05G

va-Q-tec summer

Performance : ≥ 130 hrs

KelvinHours : ≥ 3250 Khrs

va-Q-tec winter

Performance : ≥ 144 hrs

KelvinHours : ≤ -706 Khrs

va-Q-tec extreme summer

Performance : ≥ 64 hrs

KelvinHours : n.a.

va-Q-tec extreme winter

Performance : ≥ 24 hrs

KelvinHours : n.a.

va-Q-tainer USx +18G/+23G

va-Q-tec summer

Performance : ≥ 126 hrs

KelvinHours : ≥ 1260 Khrs

va-Q-tec winter

Performance : > 144 hrs

KelvinHours : < -2866 Khrs

va-Q-tec extreme summer

Performance : ≥ 32 hrs

KelvinHours : n.a.

va-Q-tec extreme winter

Performance : ≥ 60 hrs

KelvinHours : n.a.

va-Q-tainer USx -26G

va-Q-tec controlled summer

Performance : ≥ 119 hrs

KelvinHours : ≥ 5355 Khrs

va-Q-tec summer

Performance : ≥ 86 hrs

KelvinHours : n.a.

va-Q-tec extreme summer

Performance : ≥ 60 hrs

KelvinHours : n.a.

va-Q-tainer XLx Dry Ice

va-Q-tec summer

Performance : ≥ 103 hrs

KelvinHours : ≥ 10600 Khrs

va-Q-tainer XLx -37G

va-Q-tec controlled summer

Performance : ≥ 110 hrs

KelvinHours : ≥ 5489 Khrs

va-Q-tec extreme summer

Performance : ≥ 69 hrs

KelvinHours : n.a.

va-Q-tainer XLx -21G

va-Q-tec summer

Performance : ≥ 98 hrs

KelvinHours : ≥ 4929 Khrs

va-Q-tec extreme summer

Performance : ≥ 65 hrs

KelvinHours : n.a.

va-Q-tainer XLx +05G

va-Q-tec summer

Performance : ≥ 111 hrs

KelvinHours : ≥ 2853 Khrs

va-Q-tec winter

Performance : ≥ 144 hrs

KelvinHours : ≤ -706 Khrs

va-Q-tec extreme summer

Performance : ≥ 32 hrs

KelvinHours : n.a.

va-Q-tec controlled summer

Performance : ≥ 21 hrs

KelvinHours : n.a.

va-Q-tainer XLx +18G/+23G

va-Q-tec summer

Performance : ≥ 139 hrs

KelvinHours : ≥ 738 Khrs

va-Q-tec winter

Performance : ≥ 118 hrs

KelvinHours : ≤ -2384 Khrs

va-Q-tainer XLx -26G

va-Q-tec controlled summer

Performance : ≥ 115 hrs

KelvinHours : ≥ 5198 Khrs

va-Q-tainer TWINx -37G

va-Q-tec controlled summer

Performance : ≥ 103 hrs

KelvinHours : ≥ 5150 Khrs

va-Q-tec extreme summer

Performance : ≥ 63 hrs

KelvinHours : n.a.

va-Q-tainer TWINx -21G

va-Q-tec summer

Performance : ≥ 136 hrs

KelvinHours : ≥ 6773 Khrs

va-Q-tec extreme summer

Performance : ≥ 83 hrs

KelvinHours : n.a.

va-Q-tainer TWINx +05G

va-Q-tec summer

Performance : ≥ 124 hrs

KelvinHours : ≥ 3088 Khrs

va-Q-tec winter

Performance : > 144 hrs

KelvinHours : < -702 Khrs

va-Q-tec extreme summer

Performance : ≥ 47 hrs

KelvinHours : n.a.

va-Q-tec controlled summer

Performance : ≥ 20 hrs

KelvinHours : n.a.

va-Q-tainer TWINx +18G/+23G

va-Q-tec summer

Performance : ≥ 125 hrs

KelvinHours : ≥ 1238 Khrs

va-Q-tec winter

Performance : ≥ 131 hrs

KelvinHours : ≤ -2656 Khrs

va-Q-tec extreme summer

Performance : ≥ 27 hrs

KelvinHours : n.a.

va-Q-tec controlled summer

Performance : ≥ 52 hrs

KelvinHours : n.a.

va-Q-tainer TWINx Dry Ice

va-Q-tec summer

Performance : > 144 hrs

KelvinHours : ≥ 14371 Khrs

va-Q-tainer TWINx -26G

va-Q-tec controlled summer

Performance : ≥ 134 hrs

KelvinHours : ≥ 5976 Khrs

va-Q-tec summer

Performance : ≥ 91 hrs

KelvinHours : n.a.

va-Q-tec extreme summer

Performance : ≥ 65 hrs

KelvinHours : n.a.

We are there for you!

Our experts are happy to advise you on any thermal problem. We support you in all phases,

from your initial questions to the implementation.

Get help