va-Q-tainer

The va-Q-tainer is an advanced passive container, perfect for the global transportation of clinical and pharmaceutical goods. The container saves costs and simplifies handling in challenging environments. With pay-per-use-rental, scalable TempChain Services and a growing global network, the va-Q-tainer eases the work of pharmaceutical cold chain managers worldwide. The award winning container insulation enables deviation-free shipping of temperature sensitive goods, according to requirements worldwide.

Advantages of va-Q-tainer

  • Door-to-door solution for an unbroken TempChain
  • Qualified performance without payload at ambient temperature of 30 °C and 0 °C: >120h
  • 5 qualified temperature ranges from -60 °C to +25 °C available (as low as -40 °C without dry ice)
  • Comprehensive 4 size container portfolio from 1 Euro pallet to 2 US pallets payload volume
  • PMC pallet optimized: 4 Euro pallets (with 4 EUROx) or 4 US pallets (with 2 TWINx)
  • Smooth and cost saving operations: “ready to load & go” service for rental containers
  • Advanced passive technology & dry ice free (as low as -40 °C): High energy efficiency and low CO2 Emission
  • Designed for multi-use: Re-qualification of rental containers with va-Q-check® secures day-one-validation
  • Core Components & Technology “MADE IN GERMANY”
  • TempChain Service Software: Centralized management of the entire TempChain logistics process

Properties of va-Q-tainer

Dimensions

va-Q-tainer EUROx

Payload : 1200 l

Outer dimension (L x W x H) : 56.02 x 43.03 x 62.20 inch

Inner dimension (L x W x H) : 47.24 x 33.46 x 46.06 inch

va-Q-tainer TWINx

Payload : 3200 l

Outer dimension (L x W x H) : 93.70 x 58.66 x 62.20 inch

Inner dimension (L x W x H) : 83.07 x 49.21 x 48.03 inch

va-Q-tainer USx

Payload : 1800 l

Outer dimension (L x W x H) : 56.02 x 58.66 x 62.20 inch

Inner dimension (L x W x H) : 47.24 x 49.21 x 46.06 inch

va-Q-tainer XLx

Payload : 2500 l

Outer dimension (L x W x H) : 74.41 x 58.66 x 62.20 inch

Inner dimension (L x W x H) : 64.57 x 49.21 x 48.03 inch

va-Q-tainer EUROx -21G , -25 °C ... -15 °C

va-Q-tec Summer

Performance Time : ≥102 hrs

Qualified Kelvinhours : ≥5110 Khrs

va-Q-tec Extreme Summer

Performance Time : 67 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer EUROx +18G/+23G , +15 °C ... +25 °C

va-Q-tec Summer

Performance Time : ≥120 hrs

Qualified Kelvinhours : ≥1176 Khrs

va-Q-tec Winter

Performance Time : ≥120 hrs

Qualified Kelvinhours : ≤-2376 Khrs

va-Q-tec Extreme Summer

Performance Time : 30 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : 56 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer EUROx +05G , +2 °C ... +8 °C

va-Q-tec Summer

Performance Time : ≥125 hrs

Qualified Kelvinhours : ≥3163 Khrs

va-Q-tec Winter

Performance Time : >144 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Summer

Performance Time : 62 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : 33 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer TWINx +05G , +2 °C ... +8 °C

va-Q-tec Summer

Performance Time : ≥124 hrs

Qualified Kelvinhours : ≥3088 Khrs

va-Q-tec Winter

Performance Time : >144 hrs

Qualified Kelvinhours : <-702 Khrs

va-Q-tec Extreme Summer

Performance Time : 47 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : 20 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer TWINx +18G/+23G , +15 °C ... +25 °C

va-Q-tec Summer

Performance Time : >125 hrs

Qualified Kelvinhours : 1238 Khrs

va-Q-tec Winter

Performance Time : >131 hrs

Qualified Kelvinhours : -2656 Khrs

va-Q-tec Extreme Summer

Performance Time : >27 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : >52 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer TWINx -21G , -25 °C ... -15 °C

va-Q-tec Summer

Performance Time : ≥136 hrs

Qualified Kelvinhours : ≥6773 Khrs

va-Q-tec Extreme Summer

Performance Time : 83 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer USx -21G , -25 °C ... -15 °C

va-Q-tec Summer

Performance Time : 114 hrs

Qualified Kelvinhours : 5589 Khrs

va-Q-tec Extreme Summer

Performance Time : 83 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer USx +18G/+23G , +15 °C ... +25 °C

va-Q-tec Summer

Performance Time : >126 hrs

Qualified Kelvinhours : ≥+1260 Khrs

va-Q-tec Winter

Performance Time : >144 hrs

Qualified Kelvinhours : <-2866 Khrs

va-Q-tec Extreme Summer

Performance Time : 32 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : 60 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer USx +05G , +2 °C ... +8 °C

va-Q-tec Summer

Performance Time : ≥120 hrs

Qualified Kelvinhours : ≥3000 Khrs

va-Q-tec Winter

Performance Time : ≥128 hrs

Qualified Kelvinhours : ≤-640 Khrs

va-Q-tec Extreme Summer

Performance Time : 62 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : 20 hrs

Qualified Kelvinhours : Khrs

va-Q-tainer XLx +18G/+23G , +15 °C ... +25 °C

va-Q-tec Summer

Performance Time : >139 hrs

Qualified Kelvinhours : >738 Khrs

va-Q-tec Winter

Performance Time : ≥118 hrs

Qualified Kelvinhours : ≤-2384 Khrs

va-Q-tainer XLx +05G , +2 °C ... +8 °C

va-Q-tec Summer

Performance Time : ≥111 hrs

Qualified Kelvinhours : ≥2853 Khrs

va-Q-tec Winter

Performance Time : >144 hrs

Qualified Kelvinhours : -706 Khrs

va-Q-tec Extreme Summer

Performance Time : 32 hrs

Qualified Kelvinhours : Khrs

va-Q-tec Extreme Winter

Performance Time : 21 hrs

Qualified Kelvinhours : Khrs

We are there for you!

Our experts are happy to advise you on any thermal problem. We support you in all phases,

from your initial questions to the implementation.

Get help