va-Q-genic
The multi-use solution va-Q-genic enables safe shipments in cryogenic temperatures as low as -196 °C by using liquid nitrogen. The three-layer system provides resistance against mechanical impact and the vacuum insulation holds constant temperatures of up to 20 days and more. The porous material inside the dewar stores vaporized liquid nitrogen whilst constant circulation of vapor is maintained throughout the use. Direct contact with liquid nitrogen is completely avoided during product loading and unloading which allows for safe site handling for clients. The va-Q-genic is compliant with IATA Dangerous Goods Regulations and not restricted as per provision A152.

Properties of va-Q-genic
Dimensions
va-Q-genic 2
Outer dimension (L x W x H) : 11.61 x 11.61 x 19.09 inch
Inner Dimensions :
Height 4.72 inch
Neck diameter 1.18 inch
va-Q-genic 15
Outer dimension (L x W x H) : 18.70 x 19.69 x 28.35 inch
Inner Dimensions :
Height 12.20 inch
Neck diameter 3.15 inch
va-Q-genic 20
Outer dimension (L x W x H) : 18.70 x 19.69 x 28.35 inch
Inner Dimensions :
Height 11.42 inch
Neck diameter 8.46 inch
Temperature range & performance
va-Q-genic 2
ISTA 7D summer
Performance : 203 hrs
KelvinHours : 36581 Khrs
va-Q-genic 15
ISTA 7D summer
Performance : 800 hrs
KelvinHours : 144255 Khrs
va-Q-genic 20
ISTA 7D summer
Performance : 226 hrs
KelvinHours : 40755 Khrs