va-Q-med

The va-Q-med is a box optimized for integrator networks and wholesaler operations. It has a robust outer box and is designed for a long lifetime. The multi-use box is GDP compliant and is a great option for last mile or lab distribution. va-Q-tec offers the va-Q-med both as a purchase option or as a convenient rental option. 

Advantages of va-Q-med

  • Designed for domestic distribution
  • Two qualified performance levels without payload according to ISTA 7E (summer & winter profile): Standard with true 36h and more & Premium with true 54h and more
  • 5 qualified temperature ranges for shipments from -50 °C (without dry ice) to + 20 °C available (homogenous in every part of the box)
  • 2 size box portfolio: from 5 L to 18 L payload volume, optimized for fully automated process
  • Smooth and cost-saving operations: Intuitive design, all-season pack-out, transport of cooled & non-cooled goods in one vehicle
  • High energy efficiency enables low CO₂ emissions, product carbon footprint calculations are available
  • Produced in a global carbon neutral company. Technology “MADE IN GERMANY”
  • TempChain Service Software: Centralized management of the entire TempChain logistics process
  • Optional service: 100% TempChain visibility managed by va-Q-nection

Properties of va-Q-med

Dimensions

va-Q-med 7

Payload : 7 l

Outer dimension (L x W x H) : 15.75 x 11.81 x 12.80 inch

Inner dimension (L x W x H) : 9.65 x 6.50 x 6.50 inch

va-Q-med 21

Payload : 18 l

Outer dimension (L x W x H) : 23.62 x 15.75 x 13.58 inch

Inner dimension (L x W x H) : 17.32 x 9.84 x 6.30 inch

va-Q-med 7 Standard +05G

ISTA 7E summer

Performance : ≥ 21 hrs

KelvinHours : ≥ 466 Khrs

ISTA 7E winter

Performance : > 72 hrs

KelvinHours : n.a.

va-Q-med 7 Premium +05G

ISTA 7E summer

Performance : ≥ 29 hrs

KelvinHours : ≥ 661 Khrs

ISTA 7E winter

Performance : > 72 hrs

KelvinHours : n.a.

va-Q-med 7 Standard +22G

ISTA 7E summer

Performance : ≥ 47 hrs

KelvinHours : ≥ 333 Khrs

ISTA 7E winter

Performance : ≥ 20 hrs

KelvinHours : ≤ -242 Khrs

va-Q-med 7 Premium +22G

ISTA 7E summer

Performance : ≥ 48 hrs

KelvinHours : ≥ 360 Khrs

ISTA 7E winter

Performance : ≥ 33 hrs

KelvinHours : ≤ -406 Khrs

va-Q-med 7 Standard -21G

ISTA 7E summer

Performance : ≥ 18 hrs

KelvinHours : ≥ 844 Khrs

va-Q-med 7 Premium -21G

ISTA 7E summer

Performance : ≥ 33 hrs

KelvinHours : ≥ 1564 Khrs

va-Q-med 7 Premium -26G

ISTA 7E summer

Performance : ≥ 18 hrs

KelvinHours : ≥ 936 Khrs

va-Q-med 7 Premium -37G

ISTA 7E summer

Performance : ≥ 11 hrs

KelvinHours : ≥ 741 Khrs

va-Q-med 7 Premium -50G

ISTA 7E summer

Performance : ≥ 16 hrs

KelvinHours : ≥ 1238 Khrs

va-Q-med 21 Standard +05G

ISTA 7E summer

Performance : ≥ 36 hrs

KelvinHours : ≥ 806 Khrs

ISTA 7E winter

Performance : > 72 hrs

KelvinHours : n.a.

va-Q-med 21 Premium +05G

ISTA 7E summer

Performance : ≥ 47 hrs

KelvinHours : ≥ 1043 Khrs

ISTA 7E winter

Performance : ≥ 72 hrs

KelvinHours : n.a.

va-Q-med 21 Standard +22G

ISTA 7E summer

Performance : ≥ 68 hrs

KelvinHours : ≥ 496 Khrs

ISTA 7E winter

Performance : ≥ 28 hrs

KelvinHours : ≤ -344 Khrs

va-Q-med 21Premium +22G

ISTA 7E summer

Performance : ≥ 72 hrs

KelvinHours : ≥ 540 Khrs

ISTA 7E winter

Performance : ≥ 39 hrs

KelvinHours : ≤ -503 Khrs

va-Q-med 21 Standard -21G

ISTA 7E summer

Performance : ≥ 23 hrs

KelvinHours : ≥ 1083 Khrs

va-Q-med 21 Premium -21G

ISTA 7E summer

Performance : ≥ 40 hrs

KelvinHours : ≥ 1888 Khrs

va-Q-med 21 Premium -26G

ISTA 7E summer

Performance : ≥ 28 hrs

KelvinHours : ≥ 1330 Khrs

va-Q-med 21 Premium -37G

ISTA 7E summer

Performance : ≥ 22 hrs

KelvinHours : ≥ 1362 Khrs

va-Q-med 21 Premium -50G

ISTA 7E summer

Performance : ≥ 22 hrs

KelvinHours : ≥ 1696 Khrs

We are there for you!

Our experts are happy to advise you on any thermal problem. We support you in all phases,

from your initial questions to the implementation.

Get help