va-Q-vip B

Characteristics

The vacuum insulation panel va-Q-vip B is officially certified with approval No. Z-23.11-1658 from the German Institute for Building Technology (DIBT) on 21 June 2007. The core of the panel consists of a amorphous silicon dioxide powder and an inorganic opacifier. The panel is sealed under vacuum into a metallized high barrier film. The high barrier film is again covered on the exterior with a black protection fleece. The flammability of va-Q-vip B is according to DIN 4102-B2.va-Q-tec´s panels are characterized by their speical film folding technology (va-Q-seam) at the edges. Individual panels therefore can be placed together practically gapless. Other shapes are possible on request. As a check of the internal gas pressure, a sensor chip is integrated into each panel.

Applications

va-Q-vip B is specially developed for building insulation applications. The va-Q-vip B with a drastically reduced insulation thickness enable new possibilities in building insulation. va-Q-vip B has currently approved again and va-Q-tec´s panel can be used the widest field (DAD, DAA, DZ, DI, DEO, WAB, WH and WI accoridng to the standard DIN V 4108-10, table 1) in building application (Internal and external insulation, wall, floor, roof etc.).

Advantage

  • The first vacuum insulation panel approval for building application from DIBT
  • Drastically reduced heat flexes and insulation thickness
  • Increased usable space
  • Extra protection layer for safe installation

Product data

Surface colorBlack
Geometry (Without flanges*)Rectangular shape
Density (bulk, DIN EN 1602)180 - 210 kg/m³
Thermal conductivity
=> Initial value< 0.0053 W/(mK)
=> Including aging and edge losses0.0080 W/(mK)
Temperature range during application-70 °C - +80 °C
Humidity range during application0 - 60 %
Increase of gas pressureca. 1 mbar/year
Internal gas pressure< 5 mbar (at delivery)
Specific heat0.8 kJ/(kg·K)
Dimension (max.)1200 mm (L) x 1000 mm (W)
Thickness10, 15, 20, 25, 30, 40 mm
Length and width tolerance+2 / -5 mm
Thickness tolerance+/- 1 mm
U-value (with 20 mm thickness)
=> Initial value0.25 W/(m²K)
=> Including aging and edge losses0.40 W/(m²K)
Mass per area4 kg/m² (at 20 mm thickness)
External pressure load> 150 kPa at 10% compression
FlammabilityDIN 4102-B2